Brand Name : Daruifuno

Model Number : APX2-C3A/C3D

Certification : CE, ISO

Place of Origin : China

MOQ : 1

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 10000 Sets per Month

Delivery Time : 5-25 days

Packaging Details : Carton

Price : Negotiable

Product Name : PH Meter

Measurement range : -2~16pH

ORP Range : ±2000mV

Temperature Range : -10~150℃ / 14~302℉

Operating Temperature : 0~60℃

Analog output : Two 0/4~20mA

Communication : RS485 modbus RTU

Relay output : Two SPST relays

Time/Data recording : Record 14,000 historical data

Enclosure Material : Enhanced ABS

Contact Now

Modbus Or Jason Protocol PH Controller With Historical Data Recording Function

Continuous monitoring data of the APX2-C3A/C3D can be connected to the recorder through the transmission output to realize remote monitoring and recording. It can also be connected to the RS485 interface through the MODBUS-RTU protocol, which can be easily connected to the computer to realize monitoring and recording.

It adopts a design that is easy to operate, adopts a variety of self-diagnosis and output signal, alarm functions, and can carry out communication and control, data storage, and inspection of the detector.With data record function can Record 14,000 historical data; Save the last 100 maintenance data.


The built-in program has menu functions such as current output for control and electrode cleaning cycle program.

Specification:

Product Name PH ORP meter
Product Model APX2-C3A/C3D
Software Version DRFN PH Analysis software V1.0
pH Range -2~16pH
ORP Range ± 2000mV
Ground ——
Temperature Range -10~150℃ /14~302℉
Resolution 0.01pH / 1mV/ 0.1℃
Accuracy PH:±0.02 pH /ORP:±2 mV
Temperature Compensation Automatic or manual(NTC10K or PT1000)
Relay Control 2 settable SPST relays, maximum load 3A / 250VAC
Communication RS485 Modbus RTU
OTA ——
Signal Output Two 0/4~20mA current outputs maximum load 1000Ω
Sensor Diagnosis Image display
Configuration Power failure protection, indefinite retention of parameters
Time/Data recording Record 14,000 historical data; Save the last 100 maintenance data
Language Chinese and English
Protection Grade IP66
Enclosure Material Enhanced ABS
Power Supply AC: 100~240V or DC:18~36V
Dimension 144*144*120mm
Hole Size 138*138mm
Operating Temperature 0~60℃, RH<95%, non-condensing
Storage Temperature -20~70℃, RH<55%, non-condensing
Installation Method wall mounting, pipe clamp, panel
Weight 900g
Power Consumption About 7W

Please click the user manual of pH controller here:

APX2-C3 G3 pH user manual.pdf

Brief introduction:

  • Support a variety of installation methods, wall mounting, pipe clamp installation, panel installation;
  • Clock and historical data recording function to meet higher data management requirements;
  • The protection grade of the enclosure is IP66;
  • The pH ORP meter water quality transmitter can indefinitely keep the parameters;
  • The display screen is 3.2 inch, 128*64 black and white graphic dot matrix LCD screen;
  • The system provides Chinese and English language selection;
  • The material of the housing is enhanced ABS, which makes the PH ORP controller more strong and wear-resistant;
  • The screen backlight provides two models: always light and energy-saving, which can meet the different needs of users;
  • 2 settable SPST relays and 2 configurable 0/4~20mA active current loop outputs;
  • A two-wire RS485 interface, standard MODBUS RTU, can support JavaScript Object Notation text data format.​

Modbus Or Jason Protocol PH Controller With Historical Data Recording Function

Aplication:
Water treatment monitoring

Drinking water,surface water,water quality analyze,ground water,ect.

Industrial process monitoring and dosing control
Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.

FAQ
Q1. Does the instrument have a self-diagnostic function and how does it prompt?

A: The pH meter has self-diagnosis function.When the instrument is in calibration and maintenance,it can diagnose the PH/ORP sensor,if there is improper operation or poor PH/ORP sensor characteristics, the screen makes an image display and advises the user to re-maintain or replace the sensor.


Q2. What are the special advantages of the pH instruments?
A: The instrument can not only compensate the temperature of the test sample by connecting the temperature sensor, but also self-check the working temperature of the instrument in real time. When the working temperature of the instrument changes, the instrument compensates the hardware change caused by the temperature drift. Make the test results more accurate, this is a patented technology.


Product Tags:

Historical Data Recording PH Controller

      

Jason Protocol PH Controller

      

Modbus Protocol PH ORP Analyzers

      
Quality Modbus Or Jason Protocol PH Controller With Historical Data Recording Function for sale

Modbus Or Jason Protocol PH Controller With Historical Data Recording Function Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Suzhou Delfino Environmental Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)